Contact Us
- No.188 Jinjiang Raod, Dinghuo Town, Jiangdu District, Yangzhou City, China
- sales@cdpowerfitting.com
- +86-514-86978288
Down Leading ClampThe Down Leading clamp is uswd to fix the cable to splice pole/tower and terminal pole/tower in the down-lead to the closure.
Add to Inquiry
Bimetallic Bolted Mid Span JointBimetallic Bolted Mid Span Joint is mainly used for splicing connections between insulated wires, aluminum stranded wires, aluminum alloy stranded wires, and steel-cored aluminum stranded wires at
Add to Inquiry
Hydraulic Jumper ConnectorHydraulic Jumper Connectors are used to bridge two electrical components in a circuit, thereby providing a continuous flow of current. They are designed to withstand high voltage and current loads,
Add to Inquiry
Compression C ClampThe C type Clamp is made of high strength alloy of elasticity with good electrical conductivity and according to different specifications of wires, it is designed with a specific shape of wire groove
Add to Inquiry
Earthing PG ClampEarthing PG Clamp is suitable for grounding connections and high-voltage line discharge connections in overhead insulated lines of 20kV and below. Earthing PG Clamp is used in conjunction with the
Add to Inquiry
C Copper ConnectorThe c copper connector has the advantages of simple construction, small occupation area, long service life, no environmental pollution and low resistance value,etc..
Add to Inquiry
Bolted Type PG ClampThe PG clamp body and keepers are aluminium alloy, the other parts are hot-dip galvanized steel.
Add to Inquiry
Bimetallic Cable LugThe copper-aluminium bimetallic cable lugs are suitable for transition connection of the circular aluminium wires, hemicycle-sector aluminum wires, power supply cables in the distribution equipment
Add to Inquiry
C Type ClampThe C-type clamps are mainly used for 20KV overhead insulated conductors, aluminum stranded wires, steel-cored aluminum stranded wires, steel stranded wires and copper wires in non-stressed positions
Add to Inquiry
Insulated Piercing ClampThis series insulation piercing connector is mainly used for wire branching The applicable voltage is 10kV, 1kV and less more than 1kV.
Add to Inquiry
Aluminium PG Clamp for ACSRAerial insulation aluminium conductor and insulation aluminium cover are being used together action is insulation protection .
Add to Inquiry
Aluminium Compression Repair SleeveUnder the rated voltage,the splicing point temperature should not higher than the conductor temperature when through the max load electric current for long time.
Add to Inquiry